Quick note on Physical Coding Sublayer (PCS) error in Optical System

What is PCS ?

The Physical Coding Sublayer (PCS) is a networking protocol sublayer in the  Ethernet standards. This layer resides at the top of the physical layer (PHY) which provides an interface between the Physical Medium Attachment (PMA) sublayer and the media-independent interface (MII). This layer is responsible for coding and decoding data streams flowing to and from the MAC layer , scrambling and descrambling it, block and symbol redistribution, alignment marker insertion and removal, and lane block synchronisation .Currently most of the optical client ports supports PCS lane to enable high data rate .

Where actually PCS layer lies ?

 

e.g

 

How to troubleshoot PCS errors issues in Optical Network links?

If you see PCS errors on the interfaces; it may cause the link to flap or you can see errors on the client interfaces of the optical or router ports. PCS block reports signal fail/signal degrade too based on pre-set thresholds.

For PCS lane based modules like SR4,LR4 ,LR10  or multi lane pluggables ,it is recommended to see errors on the lanes of the pluggable. if only few lanes are having issue ,it is better to suspect the connector or the optical XFP/CFP.

Also there is a limit for max difference in receive/transmit power between any two lanes .If the difference is greater than the threshold it may also result in issues.

Max Difference in receive power between any two lanes

100GBASE-LR4  5.5dB
200GBASE-FR4  4.1dB
200GBASE-LR4  4.2dB
400GBASE-FR8  4.1dB
400GBASE-LR8  4.5dB

Max Difference in transmit power between any two lanes

100GBASE-LR4  5dB
200GBASE-FR4  3.6dB
200GBASE-LR4  4 dB
400GBASE-FR8  4dB
400GBASE-LR8  4.5dB

e.g 

Consider the case of using an LR4 CFP for the optical transceiver; each of the 4 wavelengths used on the link will be carrying 5 PCS lanes. In the case of 5 of the PCS lanes being in errors this may indicate the errors being specific to that wavelength and so areas of investigation should include the individual transmitters and receivers within the CFP.

If a 10 lane CFP (SR10 or LR10) is being used then each wavelength (in the case of the LR10) or fibre (in the case of the SR10) would each be carrying two PCS lanes. In this case then if two PCS lanes within the same CAUI lane are found to contain errors or defects then as well as investigating the CAUI the two lanes would also be carried on the same wavelength or fibre. In this case once again  the optical components should be investigated at both ends of the link. In the case of an SR10 based link the multi-fibre cable should also be checked as it may be possible that one of the individual fibres has been damaged within the cable.

 

CAUI -(Chip to) 100Gb/s Attachment Unit Interface

CFP :Centum Form factor Pluggable

Reference:https://testing100g.net/troubleshooting-100g-links-with-pcs-lanes/