HomeFreeInvalid Data Flag or Suspect Interval in PM(Performance Monitoring) counters

Invalid Data Flag or Suspect Interval in PM(Performance Monitoring) counters

Last Updated: August 16, 2025
3 min read
120

The ITU standards define a “suspect internal flag” which should indicate if the data contained within a register is ‘suspect’ (conditions defined in Q.822). This is more frequently referred to as the IDF (Invalid Data Flag).

PM is bounded by strict data collection  rules as defined in standards. When the collection of PM parameters is affected then  PM system labels the collection of data as suspect with an Invalid Data Flag (IDF). For the sake of identification; some unique flag  is shown next to corresponding counter.

The purpose of the flag is to indicate when the data in the PM bin may not be complete or may have been affected such that the data is not completely reliable. The IDF does not mean the software is contingent.

Some of the common reasons  for setting the IDF include:

  • a collection time period that does not start within +/- 1 second of the nominal collection window start time.
  • a time interval that is inaccurate by +/- 10 seconds (or more)
  • the current time period changes by +/- 10 seconds (or more)
  • a restart (System Controller restarts will wipe out all history data and cause time fluctuations at line/client module;  a module restart will wipe out the current counts)
  • a PM bin is cleared manually
  • a hardware failure prevents PM from properly collecting a full period of PM data (PM clock failure)
  • a protection switch has caused a change of payload on a protection channel.
  • a payload reconfiguration has occurred (similar to above but not restricted to protection switches).
  • an System Controller archive failure has occurred, preventing history data from being collected from the line/client  cards
  • protection mode is switched from non-revertive to revertive (affects PSD only)
  • a protection switch clear indication is received when no raise was indicated
  • laser device failure (affects physical PMs)
  • loss of signal (affects receive – OPRx, IQ – physical PMs only)
  • Control Plane is booted less than 15 min period for 15-min interval and less than 24 hour period for 24-hour interval.

Suspect interval is determined by comparing nSamples to nTotalSamples on a counter PM. If nSamples is not equal to nTotalSamples then this period can be marked as suspect. 

If any 15 minute is marked as suspect or reporting for that day interval is not started at midnight then it should flag that 24 Hr as suspect.

Some of the common examples are:

  • Interface type is changed to another compatible interface (10G SR interface replaced by 10G DWDM interface),
  • Line type is changed from SONET to SDH,
  • Equipment failures are detected and those failures inhibit the accumulation of PM.
  • Transitions to/from the ‘locked’ state.
  • The System shall mark a given accumulation period invalid when the facility object is created or deleted during the interval.
  • Node time is changed.
Sanjay Yadav

Optical Communications & Network Automation Expert | Author of 3 Books for Optical Engineers | Founder, MapYourTech

Optical networking engineer with nearly two decades of experience across DWDM, OTN, coherent optics, submarine systems, and cloud infrastructure. Founder of MapYourTech.

Follow on LinkedIn

Leave A Reply

You May Also Like

55 min read 14 0 Like TM Forum Open Digital Architecture Explained Skip to main content MAPYOURTECH | INDEPTH SERIES...
  • Free
  • May 29, 2026
32 min read 7 0 Like Skip to main content MapYourTech | InDepth Series Migrating From Legacy OSS and BSS...
  • Free
  • May 29, 2026
36 min read 13 0 Like The Six Levels of Autonomous Networks: L0 to L5 Skip to main content MapYourTech...
  • Free
  • May 29, 2026
Stay Ahead of the Curve
Get new articles, courses & exclusive offers first

Follow MapYourTech on LinkedIn for exclusive updates — new technical articles, course launches, member discounts, tool releases, and industry insights straight to your feed.

New Articles
Course Launches
Member Discounts
Tool Releases
Industry Insights
Be the first to know on our latest updates!.

Course Title

Course description and key highlights

Course Content

Course Details